JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Online ISSN : 1881-1299
Print ISSN : 0021-9592
EVALUATION OF THE PERFORMANCE OF THERMAL DIFFUSION COLUMN SEPARATING BINARY GAS MIXTURES WITH CONTINUOUS DRAW-OFF
ASASHI KITAMOTOMASAMI SHIMIZUYOICHI TAKASHIMA
Author information
JOURNAL FREE ACCESS

1977 Volume 10 Issue 3 Pages 211-217

Details
Abstract

Advanced transport relations involving three column constants, Hσ, Kσc and Kσd are developed to describe the separation performance of a thermal diffusion column with continuous draw-off. These constants were related to some integral functions of velocity profile, temperature distribution, density of gas mixture and characteristic values of transport coefficients.
The separation of binary gas mixture by this technique was so effective that three reasonable factors had to be introduced into the column constants in the theory. They are a circulation constant of natural convection, a definition of characteristic mean temperature and a definition of mean composition over the column.
The separation performance and the column constants also varied with the distortion of velocity profile due to continuous draw-off from the top or the bottom of column. However, its effect was not large, compared with the other factors mentioned above.
The theory presented here makes possible to estimate the separation performance of hot-wire type thermal diffusion column with high accuracy.