JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
Online ISSN : 1881-1299
Print ISSN : 0021-9592
FRICTIONAL PRESSURE DROP FOR TURBULENT GAS STREAMS IN WETTED-WALL COLUMNS WITH COCURRENT AND COUNTERCURRENT GAS-LIQUID FLOW
HARUO HIKITAKOSAKU ISHIMIHIROMU IKEKI
Author information
JOURNAL FREE ACCESS

1977 Volume 10 Issue 5 Pages 375-379

Details
Abstract
The flow behavior of the laminar liquid film and the turbulent gas stream flowing cocurrently or countercurrently in a wetted-wall column was studied theoretically and experimentally. Analytical solutions were obtained for the velocity profiles of gas and liquid and the frictional pressure drop for the gas stream. Frictional pressure drops for the gas stream were measured for the air-water system and the air-glycerol solution system. Experimental results were in good agreement with the theoretical predictions.
Content from these authors
© The Society of Chemical Engineers, Japan
Previous article Next article
feedback
Top