JAPANESE CIRCULATION JOURNAL
Online ISSN : 1347-4839
Print ISSN : 0047-1828
ISSN-L : 0047-1828
Case Report
Direct Identification of Patency Achieved by a Bi-Directional Glenn Shunt Procedure
Images by Volume Rendering Using Electron-Beam Computed Tomography
Nobusada FunabashiGeoffrey D. Rubin
Author information
JOURNAL FREE ACCESS

2001 Volume 65 Issue 5 Pages 457-461

Details
Abstract

The present study aimed to identify the patency achieved by a bi-directional Glenn shunt procedure by shaded volume rendering (VR) images using electron-beam computed tomography (EBCT). A Damus Kay-Stanzel type procedure was performed on a female with hypoplastic left heart syndrome who later received a bi-directional Glenn shunt to increase pulmonary blood flow. In considering the characteristics of the bi-directional Glenn shunt procedure, in which the superior vena cava is connected to the right pulmonary artery, an early phase acquisition protocol with injection of contrast material from the right cubital vein using the step volume scan mode of EBCT was planned to acquire blood flow information. Excellent spatial resolution volume data of the heart and great vessels was obtained from which 3-dimensional images were made. Bi-directional Glenn shunt flow could be observed directly and the complex morphology and relationships between adjacent structures were revealed by 3-dimensional VR imaging. The combination of EBCT and VR can provide useful information to evaluate congenital heart diseases. (Jpn Circ J 2001; 65: 457 - 461)

Content from these authors
© 2001 THE JAPANESE CIRCULATION SOCIETY
Previous article Next article
feedback
Top