Zairyo-to-Kankyo
Online ISSN : 1881-9664
Print ISSN : 0917-0480
ISSN-L : 0917-0480
Rapid Communication Note
Development of Zinc Plating Treatment Copper Tube to Ant's Nest Corrosion
Kenichiro Ueda
Author information
JOURNALS FREE ACCESS

2016 Volume 65 Issue 12 Pages 505-509

Details
Abstract

Recently, it has been a problem that ant's nest corrosion occur in phosphorus deoxidized copper (hereinafter called PDC) tubes for indoor equipment in room air-conditioner. We've developed zinc plating copper tube on sacrificial anticorrosion effect to ant's nest corrosion. The corrosion resistance of the tube was evaluated compared with corrosion properties of PDC and oxygen free copper (hereinafter called OFC) by vapor phase exposure test in a sealed container having a corrosive medium of 100 mg/L formic acid solution. In addition, it was also evaluated corrosive properties of OFC. Zinc plating copper tube has been completely suppressed ant's nest corrosion during corrosion test. We considered that OFC has slow corrosion property in the depth direction, because corrosion source part at bottom of corrosion hole in OFC is less than in PDC.

Information related to the author
© 2016 Japan Society of Corrosion Engineering