Establishment and Amendment of Test Standards for Evaluating Stress Corrosion Cracking Initiation in High temperature Water
Ryo IshibashiKoji FujimotoChiaki KatoYuichi MiyaharaKenji KakoKiyoko TakedaYohei SakakibaraYutaka Watanabe
Author information
JOURNAL FREE ACCESS

2018 Volume 67 Issue 11 Pages 442-449

Details
Abstract

Because of lack of test standards applicable in high-purity water at high temperatures, standardization of test methods for evaluating the stress corrosion cracking initiation of metals and alloys used for nuclear power plant has been carried out. The standard of uniaxial constant load test method has been established and stipulated in JSCE standard (JSCE S 1501). The Japan industry standard (JIS G 0511) has been reviewed and modified for the rationalization of reverse U-bend test method. Furthermore, the attempt to reflect these discussed technical resolutions in ISO standard is currently ongoing.