2019 Volume 68 Issue 12 Pages 342-346
Corrosion loss evaluation method for steel structure was investigated by acoustic emission (AE) signals with characteristics of Lamb wave. Relationship between wavelet coefficient of S0 mode of Lamb wave AE signals and AE source depth were evaluated. The amplitude of the S0 mode becomes higher as the AE source become closer to the thickness center. Thus, the corrosion depth can be evaluated by the strength ratio of S0 mode and A0 mode of Lamb wave AE signals.