防蝕技術
Online ISSN : 1884-1155
Print ISSN : 0010-9355
ISSN-L : 0010-9355
パイプラインの防食被覆の欠陥探知法に関する二, 三の実験
瀧口 周一郎蜂巣 芳雄池田 新太郎清野 喜代美
著者情報
ジャーナル フリー

1973 年 22 巻 9 号 p. 383-392

詳細
抄録

Methods of locating coating flaws and measuring insulating resistance of buried pipelines have been compared using a model pipeline which had artificial flaws. The coating systems were polyethylene and reinforced asphalt. The results show that a pin type electrode method is more sensitive than the Pearson type holiday detector in locating coating flaws. Among several procedures used for the resistance measurements, the voltage drop method is most reliable.

著者関連情報
© 社団法人腐食防食協会
前の記事 次の記事
feedback
Top