帝国石油天然ガス主管の陰極防食
福谷 英二小野 三良筧 健彦
著者情報
ジャーナル フリー

1960 年 9 巻 3 号 p. 97-99

詳細
抄録

A long natural gas main from Karikohama to Nihongi in Niigata Pref. was constructed by Teikoku Sekiyu Co. Ltd. in summer of 1959. Its extension is about 37km, and it consists of 8 in pipe line of 16km long and 10 in pipe line of 21km long. One coat of asphalt enamel and one wrap of jute were applied to the pipe and thickness of coatings is about 3mm. The coatings were tested by holiday detector, and fault places in the coatings were repaired in the field before backfilling. The gas main was divided in 3 sections by insulation flanges. A Section is located in sandy coast, and its soil resitivity is about 100, 000Ω-cm. B Section is located in Naoetsu City and in Takata City, and its soil resitivity is about 4, 000Ω-cm. C Section is located in high land district, and its soil resitivity is about 40, 000Ω-cm. Impressed current method was adopted in Section A and C. 5 sets of selenium type rectifiers (each 30V×3A) were installed on electric poles. 70 pieces of 17-D type magnesium anode were installed in Section B. Designed protective current density was 0.2mA/m2, but actual protective current density needed was about 0.1mA/m2.