防食技術
Online ISSN : 1884-1155
Print ISSN : 0010-9355
カソード防食によるステンレス鋼の応力腐食割れの防止
関口 照雄鈴木 紹夫
著者情報
ジャーナル フリー

1980 年 29 巻 4 号 p. 176-179

詳細
抄録
Cathodic protection with an external current was applied to prevent stress corrosion cracking (SCC) in a reactor vessel made of SUS 316L stainless steel containing an organic acid with 0.5%Cl-, pH 3 at 95°C. Transgranular SCC occurred mainly along the welded zone on the vessel wall after about 1 year operation without the protection. Initiation of the SCC was assisted with pitting and crevice corrosion caused by the deposition of an organic scale. A protection potential of -0.42V vs SCE and a required current density of about 10μA/cm2 were obtained by electrochemical measurements both in laboratory and field experiment. A magnetite and a pure zinc were used as the anode and the reference electrode, respectively. The SCC has been prevented successfully over 4.5 years after application of the catholic protection.
著者関連情報
© 社団法人腐食防食協会
前の記事 次の記事
feedback
Top