Zairyo-to-Kankyo
Online ISSN : 1881-9664
Print ISSN : 0917-0480
ISSN-L : 0917-0480
Comparative Study on Electrochemical Behavior of Copper Tubes in Moundless Pitting and Pitting-Free Area's Tap Water
Masahiro SakaiOsami Seri
Author information
JOURNAL FREE ACCESS

2000 Volume 49 Issue 9 Pages 557-561

Details
Abstract

The pitting corrosion of copper tubes in tap water has been investigated by electrochemical measurements. Measurements of corrosion potentials, potentiodynamic polarization tests and potentiostatic corrosion tests were carried out in two types of tap water: one type of water was taken in the area where the moundless pitting has occurred (called as ‘pitting area's water’) and another type was taken in the area where the pitting has not occurred (called as ‘pitting-free area's water’). The corrosion potential in pitting area's water was higher than that in pitting-free area's water and shifted to a nobler value gradually. Current densities of pitting area's water also indicated higher values than those of pitting-free area's water in both polarization tests and corrosion potentiostatic tests. Many visible pits existed on the surface of the specimen after the potentiostatic tests at 200mV (Ag/AgCl) in pitting area's water.

Content from these authors
© Japan Society of Corrosion Engineering
Previous article Next article
feedback
Top