Zairyo-to-Kankyo
Online ISSN : 1881-9664
Print ISSN : 0917-0480
ISSN-L : 0917-0480
The Effect of Potential Difference in the Solution of Electrochemical Measurement
Masataka MasudaEun Ju LeeKenshi HanadaMakoto Arita
Author information
JOURNAL FREE ACCESS

2004 Volume 53 Issue 5 Pages 275-278

Details
Abstract

The effect of potential difference in the solution on the electrochemical system was evaluated with the FEM (Finite Element Method) calculation. We made the theoretical analysis for the effect of Luggin capillary on the potential distribution, and the current distribution on the sample electrode. This calculation evaluated the error in the measurement of electrode potential of the electrochemical system. We proposed the optimal position of Luggin capillary for the electrode potential measurements and mentioned the deviation of the current distribution in the electrode surface by the electrode shapes and by the distance between the electrodes.

Content from these authors
© Japan Society of Corrosion Engineering
Previous article
feedback
Top