中国・四国整形外科学会雑誌
Online ISSN : 1347-5606
Print ISSN : 0915-2695
ISSN-L : 0915-2695
大腿骨転子部骨折に対する Trochanteric Plate の治療経験
藤井 裕子白形 陽生間島 直彦森野 忠夫大石 久史松田 芳郎山本 晴康石丸 公平
著者情報
ジャーナル フリー

2001 年 13 巻 2 号 p. 277-281

詳細
抄録
We treated unstable intertrochanteric fractures with the modular trochanteric plate (TP) in addition to the dynamic hip screw (DHS). The mean follow-up period was 9 months. The cases consisted of 1 male and 6 females with an average age of 85 years old (range, 76 to 93 years old). According to AO classification, all cases were 31-A2. The patient were able to bear full weight within 8 weeks after operation. In all cases callus formation was obtained within 6 to 8 weeks. Limited fracture impaction was found in 5 cases with telescoping of 4.9mm (range, 0 to 10mm). Infection, breakage of implant, and cut-out of the lag screw did not occur. In unstable intertrochanteric fractures, the addition of TP to the DHS is a favorable treatment.
著者関連情報
© 中国・四国整形外科学会
前の記事 次の記事
feedback
Top