Abstract
Background: The use of high-density barium sulfate was recommended by the Japan Society of Gastroenterological Cancer Screening (JSGCS) in 2004. We evaluated the diagnostic validity of gastric cancer screening that used high-density barium sulfate.
Methods: The study subjects were 171 833 residents of Osaka, Japan who underwent gastric cancer screening tests at the Osaka Cancer Prevention and Detection Center during the period from 1 January 2000 through 31 December 2001. Screening was conducted using either high-density barium sulfate (n = 48 336) or moderate-density barium sulfate (n = 123 497). The subjects were followed up and their medical records were linked to those of the Osaka Cancer Registry through 31 December 2002. The results of follow-up during 1 year were defined as the gold standard, and test performance values were calculated.
Results: The sensitivity and specificity of the screening test using moderate-density barium sulfate were 92.3% and 91.0%, respectively, while the sensitivity and specificity of the high-density barium test were 91.8% and 91.4%, respectively. The results of area under receiver-operating-characteristic (ROC) curve analysis revealed no significant difference between the 2 screening tests.
Conclusions: Screening tests using high- and moderate-density barium sulfate had similar validity, as determined by sensitivity, specificity, and ROC curve analysis.