Journal of Ecotechnology Research
Online ISSN : 1884-0388
Print ISSN : 1881-9982
ISSN-L : 1881-9982
Original Article
大気中のホウ素化合物の工場発生源排出濃度及び周辺環境濃度測定方法の検討
鳥山 成一近藤 隆之奥村 秀一水上 昭弘山﨑 敬久木戸 瑞佳日吉 真一郎溝口 俊明田中 敦西川 雅高
著者情報
ジャーナル フリー

2005 年 11 巻 1 号 p. 23-27

詳細
抄録
The concentrations of boron gas in the exhaust gas and in the atmosphere were measured after the removal of particles by a teflon filter with a pore size of 0.2μm . The temperature of the filter was kept at 130°C for the sampling of exhaust gas to prevent sublimation of boron compounds, while it was kept at the atmospheric temperature for the sampling of the atmospheric air. The gas-phase boron compounds was absorbed with the 3% hydrogen peroxide solution in the absorption bottle made by polypropylenes.
The measurement method by the use of ICP-MS has been established by improving many points to avoid contamination, which lowered the quantitation limit to the level of a 0.5μg/m3.
著者関連情報
© 2005 特定非営利活動法人 エコテクノロジー研究会
前の記事 次の記事
feedback
Top