保健物理
Online ISSN : 1884-7560
Print ISSN : 0367-6110
ISSN-L : 0367-6110
Technical Data
Verification of an Efficient Monte Carlo Model that Interchanges the Geometric Shapes of Plane Source and Detector in Radiation Transport Calculation
Toshiaki OMORI Shinsuke KATO
著者情報
ジャーナル フリー

2020 年 55 巻 1 号 p. 40-45

詳細
抄録

An efficient Monte Carlo computational model has been used to calculate the radiation transport when radioactive materials are deposited on an infinite plane surface, in which the geometrical shapes of the plane source and the point detector are interchanged. This transformation was verified by comparing the calculation results with the theoretical values only for the primary (unscattered) photons. It is desirable to confirm the validity of the transformation for both unscattered and scattered photons. The extension of the transformation to a finite plane source has not been verified yet. In this study, we performed calculations with and without transformation via the Monte Carlo method, and the results were compared with each other, then confirming the validity of the transformed model.

著者関連情報
© 2020 Japan Health Physics Society
前の記事 次の記事
feedback