保健物理
Online ISSN : 1884-7560
Print ISSN : 0367-6110
ISSN-L : 0367-6110
レポート
エアラインスーツ作業中のトラブル発生時におけるグリーンハウスからの退域方法の考察
―身体汚染対応用グリーンハウスの適用性評価―
浅川 潤 平野 宏志永井 佑哉會田 貴洋柴沼 智博木村 泰久
著者情報
ジャーナル フリー

2022 年 57 巻 2 号 p. 93-101

詳細
抄録

In the dismantling work of glove boxes (GBs) contaminated with radioactive materials at the nuclear fuel facilities, plastic tents are constructed around the entire GBs, and workers putting on air-fed suits (AFS) (hereinafter referred to as AFS worker) dismantle the GBs and interior equipment by using cutting tools. If an AFS worker suddenly feels sick during the work and the worker is unable to move independently, it will be necessary to exit in the shortest time from the viewpoint of respecting human life. In this case, a lot of radioactive materials may be brought into the contamination control room, thus the room and the equipment of the workers may be contaminated. Consequently, until the decontamination work is completed, the other AFS workers will have to put on AFS and wait for long time, which puts a strain on the workers. In this report, the plastic enclosure tents for body decontamination developed in JAEA were used as a new contamination control room replaced the contaminated one, and the procedure to quickly exit the remaining AFS workers was proposed. As a result, we confirmed that it was possible to greatly reduce the waiting time of the other AFS workers who were forced to wait in the dismantling area.

著者関連情報
© 2022 日本保健物理学会
前の記事 次の記事
feedback
Top