保健物理
Online ISSN : 1884-7560
Print ISSN : 0367-6110
ISSN-L : 0367-6110
Registration of Alpha Tracks in Polycarbonate Foils Using Electrochemical Etching
蘇 献章蔡 昭明
著者情報
ジャーナル フリー

1981 年 16 巻 2 号 p. 105-109

詳細
抄録

Registration of α-tracks and fast-neutron-induced recoil tracks by the electrochemical etching (ECE) technique as applied to sensitive Lexan polycarbonate foils has provided a simple, sensitive, and inexpensive means of neutron dosimetry. The application of this ECE technique to the amplification of alpha particle tracks in 250-μm-thick Lexan polycarbonate foils was studied here. The intention is to produce permanently stable tracks which are suitable for α particle detection.
The detection efficiency for α particles as a function of etching time under conditions of 1, 000V, 2kHZ, 22°C, and 50% alcoholic KOH solution was shown. It seems that the track registration efficiency is not proportional to the specific ionization in the polycarbonate foil. From the study on the relative frequency of track diameter distribution it is evident that the track diameter depends only on the latent track position in the foil.

著者関連情報
© Japan Health Physics Society
前の記事 次の記事
feedback
Top