Japanese Journal of Health Physics
Online ISSN : 1884-7560
Print ISSN : 0367-6110
ISSN-L : 0367-6110
X-Radiation from Television Receivers and Video Display Terminals
Ching-Chung HUANGPei-Huo LINYu-Ming LINPao-Shan WENG
Author information
JOURNAL FREE ACCESS

1986 Volume 21 Issue 4 Pages 265-271

Details
Abstract

This paper deals with the X-radiation from television receivers and video display terminals. The bremsstrahlung production rate was calculated according to the thick target theory, and the transmitted X-radiation was measured by the spectrometry method. The calculated and the measured results were compared and discussed. In addition, evidences were shown that only the highest energy component of the bremsstrahlung can penetrate the cathode ray tube.

Content from these authors
© Japan Health Physics Society
Previous article Next article
feedback
Top