高温学会誌
Print ISSN : 0387-1096
研究論文
高周波誘導加熱により部分熱処理したFe-Cr-Ni-Al-C合金製モ-タ用回転子の組織と磁気特性
横山 紳一郎河合 洋一南埜 宜俊
著者情報
ジャーナル フリー

2005 年 31 巻 4 号 p. 239-244

詳細
抄録
High frequency induction heating was applied to the partial austenitization treatment of the Interior Permanent Magnetic (IPM) rotor using Fe-17.6mass%Cr-2.0 mass%Ni-1.0mass%Al-0.5mass%C alloy with ferromagnetic ferrite (α) and M23C6 carbide structures, and high saturation magnetization (J) of 1.46T. Twelve bridges at the outer edge of the circular rotors were simultaneously heated by high frequency induction heating due to the increase in eddy current and Joule's heat at the bridges. The heat-treated bridges mainly consisted of paramagnetic retained austenite (γR) and a small amount of ferromagnetic martensite (α') phases with Vickers hardness number (Hv) of 274-309. The retained austenite fraction, XγR, at the bridges was estimated to be 0.70-0.80 from the relation among austenitization temperature, Hv and XγR. In addition, the J value at the bridges was estimated to be 0.16-0.27T from the relation between XγR and J values: J = 0.72XγR2 -2.19XγR+1.45. This estimated J value was almost consistent with the experimental value of 0.20T.
著者関連情報
© 2005 (社)高温学会
前の記事 次の記事
feedback