主催: 社団法人 日本エネルギー学会
会議名: 第33回石炭科学会議
回次: 33
開催地: 東京
開催日: 1996/10/28 - 1996/10/29
p. 125-128
The pressure drop occurred on the liquefaction reactors of 1t/d Process Supporting Unit (PSU) during Tanito Harum coal operation at coal concentration 50wt% conditions. It is attributable to deposits formed the principal constituent of calcite. The composition of the deposits and the relationship between the deposit formation and the operation of 1t/d PSU were discussed.