1961 Volume 11 Issue 2 Pages 96-100
This is a report on the annealing of cold-rolled high-purity aluminium. The softening, recovery and recrystallization of the metal have been studied by measuring the diffracted X-ray intensity count numbr of the all Debye-scherre rings by use of G. M counter.