Journal of the Japan Institute of Metals and Materials
Online ISSN : 1880-6880
Print ISSN : 0021-4876
ISSN-L : 0021-4876
Wettability Measurement of SiC Fibre by Liquid pure Metals (Cu, Ag, Sn) with Sessile Drop Method
Kiyoshi NogiShin-ya UesakaKazumi Ogino
Author information
JOURNAL FREE ACCESS

1989 Volume 53 Issue 8 Pages 828-833

Details
Abstract
The validity of the sessile drop method was examined to determine the wettability of the SiC fibre which has a finite curvature and contact angles of liquid pure Cu, Sn and Ag were measured on 2 types of SiC fibres.
Main results are as follows:
(1) The sessile drop method is applicable to measure the contact angle of liquid metal on SiC fibre which has a finite curvature.
(2) Liquid pure metal (Cu, Sn and Ag)/SiC fibre systems are non-wetting ones.
(3) The results obtained are comparable with the previous work for SiC substrate.
Content from these authors
© The Japan Institute of Metals
Previous article Next article
feedback