Small scale energy storage system incorporating battery bank has attracted special interest as promising load leveling system. Because battery bank voltage of this system is low, it is important to use two-quadrant chopper suitable for large step-up/step-down ratio. In this paper we propose a circuit topology of two-quadrant chopper appropriate for small scale load leveling system and present the analytical and experimental results.