Nihon Gekakei Rengo Gakkaishi (Journal of Japanese College of Surgeons)
Online ISSN : 1882-9112
Print ISSN : 0385-7883
ISSN-L : 0385-7883
CASE REPORTS
A Case with Perforation of Sigmoid Colon due to Mesh Plug for Inguinal Hernia
Koichi DeguchiHiroshi TamagawaKazuhiro IwaseHiroshi YoshidaMasaya NomuraKazuhiro NishikawaChu MatsudaTakashi DeguchiJunji KawadaYasuhiro Tanaka
Author information
JOURNAL FREE ACCESS

2014 Volume 39 Issue 2 Pages 228-233

Details
Abstract
Mesh plug repair has been one of the common methods for inguinal hernia. We report a case with perforation of sigmoid colon due to mesh plug for the repair of inguinal hernia. The patient presented peritoneal abscess forming colocutaneous and colovesicle fistula. He had previously undergone repair of left inguinal hernia with mesh plug. After diverting colostomy in transverse colon, sigmoidectomy, fistulectomy in bladder as well as removal of the prostheses were carried out. The third surgery of stoma closure finalized these procedures. A little literature described intestinal perforation due to prosthesis including mesh plug, though its incidence is very rare.
Content from these authors
© 2014 Japanese College of Surgeons
Previous article Next article
feedback
Top