The Journal of the Japanese Society for Dental Materials and Devices
Online ISSN : 2188-4188
Print ISSN : 0286-5858
ISSN-L : 0286-5858
Original Article
Non-asbestos Casting Ring Liners I
- IR and WDX analyses of liners and classification into sub groups -
Hideharu HIROSEYouji SHIOTAMakoto MATSUZAKIKiyomi MIYAZAKIJunko HAYASHIMasashi NARIKAWAMinoru NISHIYAMA
Author information
JOURNAL FREE ACCESS

1995 Volume 14 Issue 2 Pages 198-204

Details
Abstract
This study classified non-asbestos casting ring liners using IR (ATR-method) and WDX spectra. Fifteen non-asbestos casting ring liners and three asbestos ribbons were used. Non-asbestos casting ring liners were classified into five groups by IR spectra. Detected elements were Ca, Si, Al and Mg in A group, Al, Si, Ca, K and Mg in B group, Al and Si in C group, Al, Si, Ca or Zr in D group and Al, Si and Fe in E group. Asbestos ribbons consisted of Si, Mg and Fe. We identified A group as a rock-wool type, B group as a low temperature ceramic fiber type, C group as a standard ceramic fiber type, D group as a low temperature or standard ceramic fiber type and E group as a kaolin type.
Content from these authors
© 1995 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback
Top