The Japanese Journal of Ergonomics
Online ISSN : 1884-2844
Print ISSN : 0549-4974
ISSN-L : 0549-4974
Disability glare evaluation and glaremeter
T. WakeY. SHIMIZUK. TAKEUCHI
Author information
JOURNAL FREE ACCESS

1975 Volume 11 Issue 1 Pages 9-15

Details
Abstract

This paper is concerned with disability glare. A test flash was exposed for 200msec, a background or glare source were presented steadily, and the threshold vursus radiance curves were determined. According to concept of equivalent veiling luminance, degrees of disability glare is shown by the threshold vursus radiance curves. Two formulas which Holladay and Westheimer & Campbel proposed were examined from our data, and we showed that formula of Holladay is more excellent than that of Westheimer & Campbel. However, constant values of Holladay's formula do not agree under different conditions. Therefore, we proposed glaremeter that degrees of disability glare is easily measured. If we use this apparatus, subjective values will be obtained based on concept of equivalent veiling luminance.

Content from these authors
© Japan Ergonomics Society
Previous article Next article
feedback