混相流
Online ISSN : 1881-5790
Print ISSN : 0914-2843
ISSN-L : 0914-2843
Axial and Circumferential Film Flow Rate Prediction in a Horizontal Annular Two-Phase Flow Using the FIDAS-3DT Code
曹 治平菅原 悟
著者情報
ジャーナル フリー

1991 年 5 巻 2 号 p. 119-140

詳細
抄録

Prediction of developing and transient characteristics of circumferential and axial film velocities in a horizontal annular two-phase flow is carried out with the FIDAS-3DT computer code developed in Japan that can provide three-field representation in subchannel flow using the full conservative equations and simple constitutive relations. The specifications are those from a reported air-water experiment in a 3.9m by 32mm diameter pipe. Steady, fully developed axial flow rates seem to be over-predicted compared to the experimental results. A corrective procedure is suggested which takes into account the radial variation in the axial velocity profile.

著者関連情報
© The Japanese Society for Multiphase Flow
前の記事 次の記事
feedback