携帯情報端末とバーコードを利用した医薬品照合・数量管理システムによる調剤過誤並びにインシデントに対する予防効果
平野 陽子古俵 孝明五十嵐 敏明松嶋 あづさ川道 美里小島 慶之高橋 翠松井 友里恵渡瀬 友貴山下 慎司宇野 美雪上谷 幸男渡辺 享平矢野 良一塚本 仁中村 敏明岩崎 博道
著者情報
ジャーナル フリー

2017 年 43 巻 9 号 p. 502-508

詳細
抄録

In February 2015, we introduced a drug verification and quantity management system using personal digital assistants and medicine barcodes to prevent dispensing errors. We evaluated the effect of this system by comparing the number of dispensing errors and incident cases for one year before and after the introduction. The time required for dispensing was prolonged from about 28.4 seconds to 37.3 seconds per drug, about 1.3 times. The number of dispensing errors for one year before and after system introduction significantly decreased from 33.8 ± 4.7 per month to 5.8 ± 0.8 per month (P < 0.01). In addition, the number of incidents significantly decreased from 6.0 ± 0.9 per month to 3.2 ± 0.5 per month (P = 0.02). The system seems to be useful as a tool of medical safety measures because it significantly lowers the number of dispensing errors and incidents.