病院薬学
Online ISSN : 2185-9477
Print ISSN : 0389-9098
ISSN-L : 0389-9098
グリセオフルビン製剤の溶出と吸収
曽根 賢三浦 真貴子藤田 昂
著者情報
ジャーナル フリー

1984 年 10 巻 1 号 p. 17-20

詳細
抄録
Dissolution and absorption of 2 brands of griseofulvin preparation (A and B) and an inproved form of the preparation B (C) were compared. Dissolution test was made by using Sartorius Solubility Simulator. As an eluate, about 30% ethanol solution was used, because griseofulvin is insoluble in water. Amount of griseofulvin was determined by HPLC. Absorption study was made using rabbits. Plasma concentration of griseofulvin was determined by spectrofluorometer. The following results were obtained: 1) In dissolution test, 50% dissolution time of preparations A, B and C were 49 min, 63 min and 37 min, respectively. Dissolution rate at 120 min was high in the order, C>A>B, where the rate of C was significantly higher than that of the other 2. 2) In absorption test, plasma concentration of A reached its maximum in 8 hours after administration, but that of the other 2 in 6 hours. Plasma concentration of B was generally lower than those of the others.
著者関連情報
© 一般社団法人 日本医療薬学会
前の記事 次の記事