Japanese Journal of Hospital Pharmacy
Online ISSN : 2185-9477
Print ISSN : 0389-9098
ISSN-L : 0389-9098
Infection Contol by Clinical Pharmacist (2): Development of 30-Sec Handwashing-Warning Chime
AKIE KUBOTAMASAYUKI WATANABESAYOSHI NINOMIYAATSUSHI SAKOAYA FUZITATADASHI YANOTADAO FUJII
Author information
JOURNAL FREE ACCESS

1994 Volume 20 Issue 4 Pages 352-356

Details
Abstract
Since a great many microorganisms (103) were detected on the hands of nurses who used disinfectants for hygienic washing, we developed a 30-second handwashing-warning chime (scrub timer) to aid in the progreesive reduction of resident skin bacteria by disinfection. Setting the scrub timer on the dispenser of the disinfectant (povidone iodine), enables a sound to be emitted when the handwashing dispenser is pushed.
In the Plastic Surgery Department, the nurses can maintain constant contact with disinfectants for 30 seconds using the scrub timer, which serves to decrease the amount of resident hand bacteria (102) following disinfectant use more so than if the scrub timer was not used.
Using the scrub timer was concluded to be effective for handwashing with disinfectants.
Content from these authors
© Japanese Society of Pharmaceutical Health Care and Sciences