Abstract
Quality tests were performed on five brands of amoxicillin capsules (250mg potency) in terms of weight variation, disintegration and dissolution. All samples complied with the tests for weight variation and disintegration in the Japanese Minimum Requirements of Antibiotic Products, and dissolution of ingredient was rapid. Thus there was not a qualitatively questionable products. But the capsules of a brand having the largest weight variation showed the largest variation in the dissolution test.