The ordering system for injections in the total medical informational system in the Akita University Hospital was established after modifying the old system in 1999. The Auto Ample dispense (AAD) system was combined with this ordering system by TCP/IP protocol and was also introduced in our department. The stable use of this total system has been underway for the dispensation of injections since November 1999. The usefulness and efficacy of this system was evaluated in our department based on the findings of working charts, time courses, and appropriate prescriptions of the injections.
The smooth and stable dispensation of all injections using this AAD system was carried out not only for regular orders, but also for temporary orders. All nurses gave this system a favorable evaluation. The statistical data indicated that more prescription sheets were issued with this system than with the previous system, and it required much time for the packaging of injections in this system compared with the manual way. However, the efficient transport of the drugs was maintained in all wards using this system. A minor revision in this system was introduced in order to promote the appropriate dosage for every injection. The incidence of injection mistakes was thus reduced to less than 10 per month.