1992 年 3 巻 1 号 p. 29-34
The Laser Doppler velocimeter has beeen developed to evaluate the microcirculatory blood flow in human tissues. We have been used this instrument and reported the blood circulation of D-P flap and Abbe flap.
In this paper, normal tissue blood circulation was measured in maxillo-facial region by Laser Doppler Velocimeter.
The data of the microcirculatory blood flow was analyzed by using personal use computer.The software for data analyzing was developed by ourselves. The following results were obtained.
1) Normal microcirculatory blood flow at the intraoral mucosa and the facial skin were measured by Laser Doppler Veclocimeter.
2) Blood circulation values of the intraoral mucosa were larger than them of the facial skin.
3) Blood circulation values were larger in male than in female at the several points of maxillofacial region.