接着ブリッジ, スプリント用試作金合金の特性と接着力について
岩藤 健太近藤 康弘矢谷 博文山下 敦貞金 雄治間庭 秀世大塚 昌助
著者情報
ジャーナル フリー

1987 年 31 巻 2 号 p. 305-315

詳細
抄録
Because the retainers of an adhesion bridge are adhered to the lingual and a part of the proximal tooth surface with an adhesive resin, metal for the retainer necessiates the mechanical properties which are endurable of occlusal force even if it is thin. It is suspected that an adhesion bridge made of type IV gold alloy, which has been used conventionally for crowns and bridges, results in the insufficient longevity of placement because of the shortage of its toughness.
In this study we examined the mechanical properties and adhesive strength of the trial gold alloy we developed recently, whose hardness is higher than type IV gold alloy. Panavia EX® was used as an adhesive resin.
We obtained the result that the trial gold alloy has greater properties in elastic modulus, proof stress and fatigue strength than type IV gold alloy and other dental gold alloys.
Therefore, it is expected that the trial gold alloy has excellent rigidity as retainer metal for an adhesion bridge even if it is thin.
著者関連情報