日本補綴歯科学会雑誌
Online ISSN : 1883-177X
Print ISSN : 0389-5386
ISSN-L : 0389-5386
固定性臼歯架工義歯装着に伴う機能回復程度の評価
井田 治彦
著者情報
ジャーナル フリー

1989 年 33 巻 3 号 p. 682-695

詳細
抄録

The purpose of this study was to determine the degree of restoration of masticatoryfunction with fixed molar bridges. Evaluations were made of the deep temperature of themasseter muscle, masticatory performance and occlusal contacts (duration, force distribution, area and number of contacts).
Criteria were established for the parameters above mention in 30 normal subjects.
Fixed bridges were placed in 10 patients with missing only the mandibular first molar.Measurements were carried out both prior to and after placement of the prosthesis.
The following results were obtained.
1. The deep temperature of the masseter muscle patients recovered in 30 days after prosthesis.
2. The total number of contact points and contact area increased after placement by 30days.
3. The duration of occlusal contacts increased up to 30 days after placement.
4. The force distribution of occlusal contacts decreased for a time but recovered as thenormal subjects after 30 days.
5. The masticatory performance was restored immediately after the placement and showed no change by 45 days.

著者関連情報
© 社団法人日本補綴歯科学会
前の記事 次の記事
feedback
Top