日本補綴歯科学会雑誌
Online ISSN : 1883-177X
Print ISSN : 0389-5386
ISSN-L : 0389-5386
咀嚼能率表示に対する粒数測定法の検討
今岡 勢喜小澤 隆幸齊藤 実田中 茂生日比野 和人蛭川 登夫平沼 謙二
著者情報
ジャーナル フリー

1989 年 33 巻 4 号 p. 791-803

詳細
抄録

The present report discusses our new simplified measuring method of masticatory efficiency by counting particles in the matter of making test materials and the standard equation for subjects with normal dentition.
1. Two kinds of hydrocolloid impression materials, reversible and irreversible, were used as the test materials.
2. For evaluating the shape of test materials, 12 subjects with normal dentition were tested and for calculating the standard equation, 108 subjects with normal dentition were tested.
3. Each subject was investigated by the simplified method of counting particles through a sieve system. The number of remaining particles on the mesh was calculated as a masticatory performance.
4. As indicated in a previous report by Dr. Ozawa about cubical test materials, columnar test materials are easier to make than the others and these were avairable for the present particle counting method for investigating masticatory efficiency.
5. We obtained the standard equation for both kinds of test material using 108 subjects with normal dentition.
To simplify the measuring method, we selected the standard equation of a 5-mesh sieve with 10 strokes chewing for the index of masticatory efficiency. The standard equation of a 5-mesh sieve for both test materials are as follows;
1) Reversible hydrocolloid test material:
Y=-1.605X+29.058
2) Irreversible hydrocolloid test material:
Y=-1.116X+23.868
6.5, 10-mesh sieve with 10 strokes chewing showed the smallest variation in the individual coefficient of variation with both kinds of test material.

著者関連情報
© 社団法人日本補綴歯科学会
前の記事 次の記事
feedback
Top