歯科ろう付に関する研究 (第10報)
赤外線ろう付器の温度分布について
大沢 裕美萩原 芳幸誉田 雄司花村 慎也根橋 信幸山崎 大介亀田 任弘五十嵐 孝義
著者情報
ジャーナル フリー

1990 年 34 巻 3 号 p. 599-608

詳細
抄録
The purpose of this study is to measure the temperature distribution of focused energy by infra-red soldering machine. The result indicate following.
1. The three dimensional heating area is an ellipse shape, and soldering area is about 10 mm in diameter centering around the focus.
2. Temperature adjustment of INFRARED (NEY Co.) is to use Powerlevel, and of BEAMWERDER (YOSHIDA Co.) is adjusting the hight of the turn table.
3. When soldering with focused energy with infra-red machine, it is adequate to solder at the focused level or the upper level, after pre-heating of the soldering objects at the lower level.