Nihon Hotetsu Shika Gakkai Zasshi
Online ISSN : 1883-177X
Print ISSN : 0389-5386
ISSN-L : 0389-5386
Influence of Various Luting Materials on Retention of Fixed Partial Denture
Evaluation by Using Fixed Partial Denture Model Having Mandibular Third Molar as Abutment Tooth
Yoshito MinesakiJun NakaharaNaoyuki ShinoharaHiroyuki MinamiAtsuo NakashimaKenichi NagatsunaAkihiko KadokawaTadashi OnizukaTadashi Jimi
Author information
JOURNAL FREE ACCESS

1996 Volume 40 Issue 1 Pages 147-153

Details
Abstract

The laboratory fixed partial denture models, made from Ni-Cr alloy or Au-Ag-Pd alloy, were used to measure the retentive force of one retainer (full cast crown) luted on the abutment before and after thermal cycling and to evaluate the retentivity and durability of various luting materials.Three types of conventional luting materials and two adhesive resins, 4 META-MMA/TBB resin and phosphate ester composite resin, were used.
The retentive forces with adhesive resin, glass ionomer, polycarboxylate and zinc phosphatecements were 57.3-74.0, 26.3-30.6, 17.9-20.2 and 11.3-19.5 kgf respectively after 24-hour immersion in 37°C water (thermal cycle 0). There was no significant difference in the retentive force between Ni-Cr and Au-Ag-Pd alloy in all luting materials except phosphate ester composite resin. The retentive force with 4 METAMMA/TBB resin was significantly decreased by the thermal cycle test up to 50, 000 cycles, while those with other luting materials were hardly affected by thermal cycling.

Content from these authors
© Japan Prosthodontic Society
Previous article Next article
feedback
Top