OXILYZER (®) による電解水の歯科領域への応用
第3報口腔内細菌の殺菌効果について
塚崎 弘明酒井 敏博芝 華彦加瀬 智夏
著者情報
ジャーナル フリー

1997 年 41 巻 5 号 p. 830-834

詳細
抄録
Electrolyzed water is obtained at the cathode by electrolyzing tap water to which a small amountof NaCl has been added. To apply this electrolyzed water to the dental region, the germicidal effect of oralbacteria was studied.
The results were as follows:
1. All bacteria in gram-positive and fungus type strains tested were killed almost 100 percent byelectrolyzed water in 10 sec.
2. The bacteria of gram-negative were killed from 60 to 100 percent by electrolyzed water in 10 sec, except S. intermedius.
3. The germicidal effect of electrolyzed water was inhibited by organic materials containing variousproteins. These results suggested that electrolyzed water may be a very useful disinfectant in the dental regiondue to its strong killing action.