Nihon Hotetsu Shika Gakkai Zasshi
Online ISSN : 1883-177X
Print ISSN : 0389-5386
ISSN-L : 0389-5386
A Study on Tensile Bond Strength of Silicone-rubber Soft Relining Material: Denture Relining® to Various Denture Base Materials
Hideharu HiroseToyonori InoueNobuyuki YamanakaJunko HayashiYugen OhkiMinoru Nishiyama
Author information
JOURNAL FREE ACCESS

1999 Volume 43 Issue 2 Pages 335-343

Details
Abstract
The tensile bond strength (TBS) to denture base materials of silicone-rubber soft relining materials (DRS: Denture Relining Soft type, GC) immersed in water at 37°C from 1 day to 8 weeks was investigated. Four denture base metals (18 K-Au alloy, Ag-Pd-Au alloy, Co-Cr alloy and Pure Ti) and two denture base resins (polycarbonate resin and polysulfon resin) were used. The TBS of DRS was 1.39-2.05 MPa to denture base metals and 1.59-1.81 MPa to denture base resin after 1-dayimmersion, and 1.59-2.75 MPa and 1.47-2.33 MPa respectively after 8-week immersion. These values were significantly superior to those of two ordinary silicone-rubber relining materials.
Content from these authors
© Japan Prosthodontic Society
Previous article Next article
feedback
Top