Nihon Rinsho Geka Gakkai Zasshi (Journal of Japan Surgical Association)
Online ISSN : 1882-5133
Print ISSN : 1345-2843
ISSN-L : 1345-2843
Case Reports
A Case of Abscess of the Rectus Abdominis Muscle Formed as a Result of Mispositioning of a Central Venous Catheter Inserted into the Femoral Vein in the Inferior Epigastric Vein
Masakazu OHNO, Yuta YAMAZAKI, Takahiro NAKAJIMA, Shiro TAKASE, Nobuya KUSUNOKI, Tetsuo AJIKI
Author information
JOURNAL FREE ACCESS

2016 Volume 77 Issue 3 Pages 687-691

Details
Abstract
A 66-year-old woman presented to us with the complaint of dysphagia and a central venous catheter (CVC) was inserted into the right femoral vein for parenteral nutrition. On day 8 after the catheter insertion, the patient complained of right lower abdominal pain. She also developed high fever and an abdominal wall mass, which was suspected as an abscess, and was transferred to our hospital on day 11 after the catheter insertion. Abdominal ultrasonography showed a lesion with heterogeneous internal echoes, suggestive of an abscess, in the rectus abdominis muscle. Computed tomography revealed an abscess in the rectus sheath and the misinserted CVC in the inferior epigastric vein. Operation was performed for abscess drainage, and the CVC was found in the abscess. This rare case involved a CVC inserted into the right femoral vein reaching the inferior epigastric vein. We must pay attention to possible aberrant mispositioning of a CVC after insertion.
Content from these authors
© 2016 Japan Surgical Association
Previous article Next article
feedback