実験力学
Print ISSN : 1346-4930
ISSN-L : 1346-4930
解 説
ホログラフィによる微粒子計測
田中 洋介
著者情報
ジャーナル フリー

2020 年 20 巻 2 号 p. 95-100

詳細
抄録

   This review paper provides particle measurements using holography as a guide for the beginner. Especially, phase retrieval holography with two high-speed cameras is explained by comparing with conventional Gabor holography. Additionally, we introduce a graphic processing unit (GPU) acceleration to reconstruct holograms. Conventional holography has two problems: the twin image problem and reconstructed particle elongation. The first problem causes blurred and low contrast particles due to the lack of phase information. Phase retrieval holography can resolve this problem with several holograms recorded at different positions. The particle elongation is that a spherical particle is elongated in the optical axis in the reconstructed process. The elongation is proportional to the relationship between particle diameter and the wavelength of recording hologram. This relationship can precisely measure the microparticle diameter more than the measured diameter in the recorded plane with low resolution. This review paper demonstrates the observation of the three-dimensional trajectory of microdroplet and measurement of droplet diameter with the elongation using phase retrieval holography.

著者関連情報
© 2020 日本実験力学会
前の記事 次の記事
feedback
Top