非破壊検査
Print ISSN : 0367-5866
形状が不規則な部位における超音波探傷試験に用いる音響カプラの材質に関する基礎的検討
福冨 広幸
著者情報
ジャーナル フリー

2023 年 72 巻 12 号 p. 554-558

詳細
抄録

The Adaptive Total Focusing Method (ATFM), which can be applied to an irregular surface, has been attracting attention in the field of phased array ultrasonic testing for power plants and chemical plants, and its introduction into ultrasonic testing for plants is being considered. When ATFM is applied to an irregular surface, such as a weld cap of piping in a power plant, a gel acoustic coupler is promising from the viewpoint of workability in the field. Segmented Polyurethane Gel (SPUG), which is like water in sound velocity and density, is beginning to be used in ultrasound imaging in the medical field. This paper discusses the use of SPUG as a material for acoustic couplers in the field application of ATFM, and examines the behavior of SPUG in contact with water, machine oil, glycerin paste, and epoxy resin, and shows examples assuming the wall thickness measurement of steel structures and delamination inspection of glass fiber reinforced resin.

著者関連情報
© 2023 (一社)日本非破壊検査協会
feedback
Top