Journal of the Japan Society for Precision Engineering
Online ISSN : 1882-675X
Print ISSN : 0912-0289
ISSN-L : 0912-0289
Development of Fastener Performance Testing Machine for Bolted Joint Tightened in Elastic or Plastic Region
Kazuo MARUYAMAHirokazu TSUJIKoichi ICHIHARA
Author information
JOURNAL FREE ACCESS

1988 Volume 54 Issue 10 Pages 1933-1938

Details
Abstract

In this study, a micro-computer-aided testing machine is designed and produced by way of experiment, which can realize various fastener tightening methods in elastic or plastic region and continuously apply an external force on the fastener. It consists of a DC-servo motor, a hydraulic cylinder, a new-type load cell, a new-type extensometer and a micro-computer, and can detect following nine factors : tightening torque, thread torque, bearing surface torque, axial tension, external force, elongation of bolt, torsional angle of bolt, rotational angle of nut, time. They are processed in a micro-computer and recorded on an X-Y plotter. Fundamental test was made with the bolts and the nuts of M 10 in elastic or plastic region of bolt material, and it is confirmed that the testing machine satisfies the specifications needed.

Content from these authors
© by The Japan Society for Precision Engineering
Previous article Next article
feedback
Top