日本輸血学会雑誌
Online ISSN : 1883-8383
Print ISSN : 0546-1448
ISSN-L : 0546-1448
γ線照射RC-MAPのフィルター濾過による影響
長橋 久方森山 哲坪倉 兌雄田所 憲治中島 一格十字 猛夫
著者情報
ジャーナル フリー

1998 年 44 巻 3 号 p. 322-327

詳細
抄録

Gamma irradiation for red cell M. A. P (RC-MAP) is used to prevent transfusion-associated graft-versus-host disease. In this study, we examined changes in supernatant potassium, hemoglobin concentrations and red cell ATP values in irradiated RC-MAP filtered through a bedside filter.
RC-MAP was stored under usual conditions for seven days after γ-ray irradiation with 137Cs with an IBL 437C-III (CIS Bio International). Irradiated RC-MAP was filtered through a bedside filter (Sepacell RZ-200A-W) in vitro at a flow rate of 5ml per minute. Although supernatant hemoglobin concentrations were significantly increased by filtration, no difference was observed between the nonirradiated controls and irradiated units in the rate of increase.
There were no significant changes in supernatant potassium concentration or red cell ATP value by filtration. Irradiation had no effect on leukocyte reduction rate or red cell and platelet recovery rate. The number of residual leucocytes after filtration was reduced to 103 cells/bag level in all cases.

著者関連情報
© 日本輸血・細胞治療学会