2003 年 49 巻 5 号 p. 660-665
In the present study, we investigated the effects of radiation and leukocyte-reduction filters on platelet function. Platelet aggregation in response to collagen and ADP were measured prior to and after irradiation and filtration, as were the platelet recovery rate and complement factor C3. Four types of leukocyte-reduction filter were used, namely positively-, negatively-, and non-charged filters (all of polyester composition), as well as a polyurethane filter. Radiation itself did not significantly affect either the platelet recovery rate, platelet function, or C3 value. On the other hand, filtration through polyester leukocyte-reduction filters resulted in a significant reduction in the platelet recovery rate, an effect not observed with the polyurethane filter. However, none of the filters caused significant changes in platelet function or in C3 value. We concluded that radiation and filtration do not cause significant changes in platelet function, but polyurethane filters are superior to polyester filters in relation to platelet recovery.