Journal of Light & Visual Environment
Online ISSN : 1349-8398
Print ISSN : 0387-8805
ISSN-L : 0387-8805
Papers
A Study on the Practical Use of a Task and Ambient Lighting System in an Office
Kazumi YAMAKAWAKoji WATABEMinoru INANUMAKatsuhiko SAKATAHitoshi TAKEDA
著者情報
ジャーナル フリー

2000 年 24 巻 2 号 p. 2_15-2_18

詳細
抄録
The possibility of the practical use as an office lighting system, which make the total illuminance of 400lx and Task and Ambient illuminance ratio of 1.0 on the working desk, by using Task and Ambient Lighting system was reported on the last year research. On this year research, the following aspects were indicated based on the analysis of the psychological queries after two weeks actual work in the specific illuminance level and Task and Ambient illuminance ratio. The illuminance level of 200lx on a working desk cause some psychological problem as room and desk area ‘darkness’ and illuminance level ‘unevenness’. These problems were improved when the illuminance level of 300lx was applied. And this analysis suggested that the Task and Ambient illuminance ratio shall be around 1.0. An approximately 20% saving energy can be achieved under this lighting system condition compared with the general office lighting system.
著者関連情報
© 2000 The Illuminating Engineering Institute of Japan
前の記事 次の記事
feedback
Top