The Journal of Medical Investigation
Online ISSN : 1349-6867
Print ISSN : 1343-1420
ISSN-L : 1343-1420
Texture analysis of sonographic muscle images can distinguish myopathic conditions
Hiroyuki NoderaKazuki SogawaNaoko TakamatsuShuji HashiguchiMiho SaitoAtsuko MoriYusuke OsakiYuishin IzumiRyuji Kaji
著者情報
ジャーナル フリー

2019 年 66 巻 3.4 号 p. 237-247

詳細
抄録

Given the recent technological advent of muscle ultrasound (US), classification of various myopathic conditions could be possible, especially by mathematical analysis of muscular fine structure called texture analysis. We prospectively enrolled patients with three neuromuscular conditions and their lower leg US images were quantitatively analyzed by texture analysis and machine learning methodology in the following subjects :  Inclusion body myositis (IBM) [N=11] ; myotonic dystrophy type 1 (DM1) [N=19] ; polymyositis/dermatomyositis (PM-DM) [N=21]. Although three-group analysis achieved up to 58.8% accuracy, two-group analysis of IBM plus PM-DM versus DM1 showed 78.4% accuracy. Despite the small number of subjects, texture analysis of muscle US followed by machine learning might be expected to be useful in identifying myopathic conditions. J. Med. Invest. 66 : 237-240, August, 2019

著者関連情報
© 2019 by The University of Tokushima Faculty of Medicine