主催: The Japan Society of Mechanical Engineers
会議名: The Ninth International Conference on Modeling and Diagnostics for Advanced Engine Systems (COMODIA 2017)
開催日: 2017/07/25 - 2017/07/28
Urea Selective Catalytic Reduction (urea SCR) system is widely used for diesel engine to reduce the emission of NOx by NH3 which is provided by a hydrolysis of urea water. Concentration distribution of NH3 in an exhaust pipe is an important factor for improvement of the SCR efficiency and prevention of NH3 slip and urea deposit. Therefore it is necessary to measure two-dimensional (2D) concentration of NH3 in detail. The purpose of this study is to develop the real-time two cross-sectional measurements technology of NH3 concentration using the computed tomography-tunable diode laser absorption spectroscopy (CT-TDLAS). This method was employed in a bend pipe model demonstrated a urea SCR system. The experimental results of two cross-sectional 2D concentration of NH3 show differences of the concentration distribution of NH3 each cross-section and flow pattern like swirl flow. These results were compared to calculated results using computational fluid dynamics (CFD) and the experimental results of NH3 flow characteristics are agree very well with the calculated results. It was found that CT-TDLAS was an effective method to measure concentration distribution of NH3 and observe characteristics of flow.