気象集誌. 第2輯
Online ISSN : 2186-9057
Print ISSN : 0026-1165
ISSN-L : 0026-1165
温位係數(760/N)0.288及び(750/N)0.288の表
山口 悟
著者情報
ジャーナル フリー

1939 年 17 巻 3 号 p. 105-106

詳細
抄録

The values of potential temperature factors K=(760/N)0.288 and (750/N)0.288 for intervals of one mm Hg from 779 to 50mm Hg have been calculated and tabulated for use in the computation of the potential temperature. The potential temperature is expressed in the following formula θ=T(760/N)0.288 and θ=T(750/N)0.288 where T the actual temperature in °A and N the pressure in mm Hg. The potential temperature, of which standard pressure being 760mm Hg or 1000mb (750mm), can be computed merely by multiplying the actual temperature in °A by the proper factor K found from the table.

著者関連情報
© 社団法人 日本気象学会
前の記事
feedback